The PPS71 G-CCL Geothermal Tools are designed for extreme, high temperature downhole conditions. The robust electronics combined with vacuum flask technology allow these products to perform at 350 °C (662 °F) continuously, for four hours. The tool measures casing collar location, and gamma rays, and can be configured as either a memory tool or surface read out tool (SRO) tool.

PDF Icon  PPS71 G-CCL Data Sheet

 

Specifications

Pressure Sensor TypeSilicon Sapphire
Pressure Range5K psi | 10K psi
Accuracy± 0.03% FS
Resolution0.0003% FS
 
Temperature Sensor TypeRTD (Pt1,000; 4-wire)
Temperature Range300 °C (572 °F) | 350 °C (662 °F)
Accuracy± 0.5 °C
Resolution0.01 °C
 
Flow Profile Sensor TypeReed Switch/magnetic
Spinner Range5 – 7,000 RPM
Accuracy (< 20 RPS)± 0.5 revolution
Accuracy (> 20 RPS)± 0.25 revolution
Resolution (< 20 RPS)0.5 RPS
Resolution (> 20 RPS)0.1 RPS